- Provides protection from fire and carbon monoxide in one unit with Photoelectric sensor..
- Fire warning - The red LED will flash and be accompanied by three long alarm beeps followed by a verbal warning message “Fire Fire” The alarm will repeat pattern until unit is reset or smoke is eliminated..
- Carbon monoxide warning - Four short alarm beeps followed by a verbal warning “Warning, Carbon monoxide” This continues until the unit is reset or the CO is eliminated..
- Low battery warning - One chirp followed by warning “low battery”. The red LED light will flash. This pattern will continue every minute for the first hour. After the first hour the red LED light will flash once every minute accompanied by the chirp sound. The “low battery” warning will only sound once every fifteen minutes. Voice Hush Indication: “Hush activated” and “Hush cancelled” voice announcement.
- Alarm memory - The green LED will blink once every 16 seconds to alert a user when the unit has alarmed for smoke or has detected a concentration of CO. If the alarm has detected a CO level of 100ppm or greater, when the test/reset button is pressed the unit will announce “CO previously detected”. If the alarm has detected abnormal levels of smoke since its last test, it will produce three rapid beeps..
- AC-Wire with battery backup, An included 9V battery protects during short-term power outages.
- Front-loading battery with unique battery door design.
- Voice warning with green and red LEDs.
- Photoelectric smoke sensor – May detect visible fire particles associated with slow smoldering fires sooner than an ionization sensor..
- Tamper resistant.
Product Description
-------------------
The Kidde Front-Loading Smoke and Carbon Monoxide alarm (part
21007624) offers protection from two hazards – fire and CO – in
one unit. Sold under the FireX brand, this AC-wire with battery
backup alarm emits a beeping tone followed by a voice warning
that clearly announces the danger by saying, “Fire Fire” or
“Warning Carbon Monoxide”. The uniquely designed frontloading
battery compartment makes battery replacement quick and easy, and
ensures proper installation. Manufactured with photoelectric
sensors for detecting smoke and fire, this alarm also includes
the world’s most accurate CO sensing technology based on cls
by major manufacturers. Architectural and Engineering
Specifications - The combination smoke and carbon monoxide alarm
shall be Kidde Unit Number KN-COPE-I (part number 900-0213) or
approved equal. It shall be powered by 120VAC, 60Hz source with a
9V battery backup. The temperature operating range shall be
between 40°F and 100°F (4°C and 38°C) and the humidity operating
range shall be 5% - 95% relative humidity. The unit shall
incorporate a photoelectric smoke sensor with nominal sensitivity
of 2.05%/ft. The CO sensor shall be of a fuel cell design and
shall meet the sensitivity requirements of Underwriters
Laboratories UL2034 Single and Multiple Station Carbon Monoxide
Detectors. The unit shall qualify for UL-approved wording on the
package: “World’s Most Accurate Carbon Monoxide Alarm”. The
combination alarm can be installed on the surface of any wall or
ceiling following the UL/NFPA/Manufacturer’s recommended
placement guidelines. The alarm can be installed on any standard
single gang electrical box, up to a 4”octagon junction box. The
electrical connection (to the alarm) shall be made with a plug-in
connector. The unit shall provide optional tamper resistance that
deters removal of the unit from the wall or ceiling. No
additional pieces shall be required to activate this feature. A
maximum of 24 Kidde devices can be interconnected in a multiple
station arrangement. The interconnect system must not exceed the
NFPA (National Fire Protection Association) limit of 18
initiating devices, of which 12 can be smoke alarms. With 18
initiating devices (smoke, heat, CO, etc), interconnected, it is
still possible to interconnect 6 strobe lights and or relay
modules. The alarm shall include a test button that will
electronically simulate the presence of smoke and CO and cause
the unit to go into both modes of alarm. This sequence tests the
unit’s electronics to ensure proper operation. The CO sensor will
not alarm to levels of CO below 30 ppm and will alarm in the
following time range when exposed to the corresponding levels of
CO. 70 ppm CO Concentration 60 – 240 minutes 150 ppm CO
Concentration 10 – 50 minutes 400 ppm CO Concentration 4 – 15
minutes The combination alarm shall have two methods of warning
for danger: a piezoelectric horn that is rated at 85 decibels at
10 feet and a voice warning that identifies the danger. For a CO
incident, the horn will sound in the repetitive manner – four (4)
fast beeps, a short pause, four (4) fast beeps, a short pause. In
between, the unit will announce “Warning Carbon Monoxide” In a
Smoke incident, the horn will sound in the repetitive manner –
three (3) beeps, a pause, three (3) beeps, and a pause. In
between, the unit will announce “Fire Fire” The unit shall
incorporate 2 LED’s. A green LED will be steady on when AC power
is present, flash every 30 seconds when in the battery only mode,
every 16 seconds to indicate alarm memory, and every 2 seconds to
indicate the Hush“mode is active. A red LED will flash in unison
with the sounder pattern. The unit shall include the Smart Hush
feature that silences the unit for approximately 8 minutes if a
nuisance alarm condition occurs. The Green LED on the alarm will
flash every 2 seconds while in Smart Hush and will automatically
reset itself. It also provides voice annunciation of “Hush
Activated” when Smart Hush is activated and “Hush Cancelled” when
the Hush cycle ends. The unit shall also indicate a low battery
warning utilizing each of the following methods: a brief alarm
chirp, the voice announcement of “Low Battery” The unit shall at
a minimum meet the requirements of UL 2034, UL217, NFPA72,
(chapter 11 2002 edition) The State of California Fire Marshall,
NFPA101 (One and two family dwellings) Federal Housing Authority
(FHA), Housing and Urban Development (HUD). It shall also include
a 10-year manufacturer’s limited warranty. Cl approved by UL,
based on manufacturer’s reported testing.
.com
----
Kidde Photoelectric Combo Alarm view larger
( https://images-na.ssl-images-.com/images/G/01/th/us/kidde/B003A6249Q_left_large._V360651217_.jpg )
Alarm placements view larger
( https://images-na.ssl-images-.com/images/G/01/th/us/kidde/B003A6249Q_right_large._V360651216_.jpg )
Firex 21007624 AC Wire-in Combination Carbon Monoxide &
Photoelectric Smoke Alarm with Battery Back-up
-----------------------------------------------------------------
The Firex Front-Loading Smoke and Carbon Monoxide alarm by Kidde
(part # 21007624) offers protection from two hazards – fire and
CO – in one unit. This AC-wire with battery backup alarm emits a
beeping tone followed by a voice warning that clearly announces
the danger by saying, “Fire! Fire!” or “Warning! Carbon
Monoxide!”. The uniquely designed frontloading battery
compartment makes battery replacement quick and easy, and ensures
proper installation. Manufactured with photoelectric sensors for
detecting smoke and fire, this alarm also includes the world’s
most accurate CO sensing technology based on cls by major
manufacturers.
Consumer benefits
-----------------
A combination alarm provides a 2 in 1 protection against fire
and carbon monoxide. Properly installed and maintained, smoke
alarms are one of the best and least expensive ways to provide
early warning when a fire begins. Smoke alarms save lives,
prevent injuries and minimize property damage by alerting
residents to a fire hazard.
Sensor Technology
-----------------
This alarm uses a photoelectric sensing technology that detects
visible particles associated with smoldering fires sooner than
ionization alarms. Ionization alarms detect invisible fire
particles associated with flaming fires sooner than photoelectric
alarms. Kidde recommends that both types of alarms be installed
inside the home to protect against both types of fires.
Smoke Alarm Tips
----------------
Install smoke alarms on every floor of your home, in hallways,
inside bedrooms and outside of ing areas. On average,
families have less than three minutes from the time the first
smoke alarm sounds to escape a fire. The sooner you hear an
alarm, the more time you will have to get out.
What's in the box
-----------------
One single Firex 21007624 AC Wire-in Combination.
At-a-glance
-----------
* Offers protection from 2 hazards, fire & CO, in 1 unit
* AC wire with battery back-up alarm emits a beeping tone
followed by voice warning
* Front loading battery compartment makes battery replacement
quick & easy
* Manufactured by Kidde with photoelectric sensors for detecting
smoke & fire
* Alarm includes the world's most accurate CO sensing technology
P.when('A').execute(function(A) {
A.on('a:expander:toggle_description:toggle:collapse',
function(data) {
window.scroll(0, data.expander.$expander[0].offsetTop-100);
});
});
From the Manufacturer
---------------------
Front-loading smoke and carbon monoxide alarm offers protection
from both fire and CO in one unit. AC-wired with battery backup
alarm emits beepoing tone followed by a voice warning. The
uniquely designed front-loading battery compartment makes battery
replacement quick and easy and ensures proper installation. Made
with photoelectric sensors for detecting smoke and fire, this
alarm also includes the world's most accurate CO sensing
technology.
See more ( javascript:void(0) )